FEATURES :

  • Complies with OIML R60 C3 (Emax≥1kg) regulations up to 5 000d for scales class III
  • Over-load protection
  • Off-center load compensated
  • Protection to IP66
  • Explosion proof version (Ex ib II CT4)

Download Brochure

Request Quote
Empty tab. Edit page to add content here.

Type

108AA

Accuracy class according to OIML R60


C3

Maximal numbers of load cell verification intervals (nLC)


5 000

Maximal capacity (Emax)

kg

0.1;0.2;0.3;0.5

1;2;3;5

Minimum load cell verification interval (Vmin)

% of Cn

 

0.02

Reference Max.platform size

mm

200×200

230×230

Sensitivity (Cn)

mV/V

1±20%

2±20%

Zero balance

mV/V

±0.05

±0.05

Temperature effect on sensitivity (TKc) *

% of Cn/k

< ±0.0017

< ±0.0012

Temperature effect on zero balance (TKo)

% of Cn/k

< ±0.0120

< ±0.0040

Non-linearity (dlin) *

%

< ±0.023

< ±0.017

Repeatability (drep) *

%

< ±0.023

< ±0.017

Hysteresis error (dhy) *

%

< ±0.023

< ±0.017

Creep (dDR)in 30 min.

%

< ±0.05

< ±0.023

Input resistance (RLC) [Red(+)-black(-)]

Ω

415 ±15

Output resistance (RO) [Green(+)-White(-)]

Ω

350±3

Reference excitation voltage (Uref)

V(DC/AC)

0.5…12

Maximal excitation voltage

V(DC/AC)

18

Insulation resistance (Ris)


>1 (50 VDC)

Nominal temperature range

°C (oF)

-10…+40 (15…+105)

Service temperature range

°C (oF)

-10…+50 (15…+122)

Storage temperature range

°C (oF)

-25…+70 (-13…+158)

Safe load limit (EL)

% of Cn

150

Breaking load (Ed)

% of Cn

300

Weight (G), approx.

kg

0.1

Protection class (IP) acc. to IEC529


IP66

Material


Aluminum

Optionally


Explosion proof version(Ex ib II CT4)